:MEASure Subsystem Spectrum Analyzer Commands
6-44 PN: 10580-00306 Rev. E MS20xxC PM
Measure Channel Power/Density
:MEASure:CHPower?
Description: Sets the active measurement to channel power, sets the default
measurement parameters, triggers a new measurement, and returns
the channel power and channel power density results. It is a
combination of the commands :CONFigure:CHPower;
:READ:CHPower? For a description of the default channel power
measurement parameters, refer to :CONFigure:CHPower. To make a
channel power measurement with settings other than the default values
send:
:CONFigure:CHPower
Commands to set desired settings
:READ:CHPower?
Data is returned as 2 comma-separated values: channel power, channel
power density.
Syntax: :MEASure:CHPower?
Cmd Parameter: NA (query only)
Default Unit: Current amplitude units
Related Command: :MEASure:CHPower:CHPower?