Spectrum Analyzer Commands :CALCulate Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 6-15
To turn off upper limit:
:CALCulate:LIMit:UPPer OFF
:CALCulate:LIMit:UPPer 0
:CALCulate:LIMit:UPPer:STATe 0
Related Command: :CALCulate:LIMit[:STATe]
Front Panel
Access: Shift-6 (Limit), On/Off
Move Limit
:CALCulate:LIMit:VALue
Description: Sets the currently active limit line value. This command moves an
entire single or multi-segment limit line up or down by the given
<value>. This command is equivalent to the command
:CALCulate:LIMit:Y. Use :CALCulate:LIMit:TYPe to set the
currently active limit line.
Note that this changes the Move Limit on the front panel to Limit if it is
currently set to Point.
Syntax: :CALCulate:LIMit:VALue <value>
Cmd Parameter: <value>
Query Response: <value>
Default Unit: Current y-axis unit.
Related Command: :CALCulate:LIMit:Y
:CALCulate:LIMit:TYPe
Front Panel
Access: Shift-6 (Limit), Limit Edit, Amplitude
Add Vertical
:CALCulate:LIMit:VERTical:ADD
Description: Adds vertical. This adds two inflection points that share the same
frequency and that are centered midpoint between adjacent points. Use
:CALCulate:LIMit:TYPe to set the currently active limit line.
Syntax: :CALCulate:LIMit:VERTical:ADD
Related Command: :CALCulate:LIMit:TYPe
Front Panel
Access: Shift-6 (Limit), Limit Edit, Add Vertical

Table of Contents