[:SENSe] Subsystem Spectrum Analyzer Commands
6-74 PN: 10580-00306 Rev. E MS20xxC PM
Resolution Bandwidth
[:SENSe]:BANDwidth|BWIDth[:RESolution]
Description: Sets the resolution bandwidth. Note that using this command turns the
automatic resolution bandwidth setting OFF.
Syntax: [:SENSe]:BANDwidth|BWIDth[:RESolution] <freq>
[:SENSe]:BANDwidth|BWIDth[:RESolution]?
Cmd Parameter: <freq>
Query Response: <freq>
Range: 10 Hz to 3 MHz in a 1:3 sequence
Default Value: 3MHz
Default Unit: Hz
Related Command: [:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO
Front Panel
Access: BW, RBW
Resolution Bandwidth Coupling
[:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO
Description: Sets the state of the coupling of the resolution bandwidth to the
frequency span. Setting the value to ON or to 1 results in the resolution
bandwidth being coupled to the span. That is, when the span changes,
the resolution bandwidth changes. Setting the value to OFF or to 0
results in the resolution bandwidth being uncoupled from the span.
That is, changing the span does not change the resolution bandwidth.
When this command is issued, the resolution bandwidth setting itself
does not change, only the coupling is affected. The default value is ON.
That is, sending :SENS:BAND:RES:AUTO is equivalent to sending
:SENS:BAND:RES:AUTO ON.
Syntax: [:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO OFF|ON|0|1
[:SENSe]:BANDwidth|BWIDth[:RESolution]:AUTO?
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: ON
Related Command: [:SENSE]:BANDwidth|BWIDth[:RESolution]:RATio
Front Panel
Access: BW, Auto RBW

Table of Contents