:CALCulate Subsystem Spectrum Analyzer Commands
6-24 PN: 10580-00306 Rev. E MS20xxC PM
Marker Counter
:CALCulate:MARKer{1|2|3|4|5|6}:FCOunt[:STATe]
Description: Turns the marker frequency counter on or off. The marker counter is
turned off when the selected marker is turned off. If delta marker is on
when setting marker counter to on, then delta marker is turned off. If
noise marker is set to on when setting marker counter to on, then noise
marker is set to off. This command is not valid in zero span.
Syntax: :CALCulate:MARKer{1|2|3|4|5|6}:FCOunt[:STATe]
OFF|ON|0|1
:CALCulate:MARKer{1|2|3|4|5|6}:FCOunt[:STATe]?
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: OFF
Example: To turn on frequency counter for reference marker #2:
:CALCulate:MARKer2:FCOunt ON
:CALCulate:MARKer2:FCOunt 1
Front Panel
Access: Marker, More, Counter Marker
Marker Fixed State
:CALCulate:MARKer{1|2|3|4|5|6}:FIXed[:STATe]
Description: Sets the specified reference marker fixed state on or off. If Fixed is set to
on, then the selected reference markers stay at the currently-set
amplitude when the marker is set to Fixed.
Syntax: :CALCulate:MARKer{1|2|3|4|5|6}:FIXed[:STATe] OFF|ON|0|1
:CALCulate:MARKer{1|2|3|4|5|6}:FIXed[:STATe]?
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: OFF
Example: To set reference marker #1 to fixed:
:CALCulate:MARKer:FIXed ON
:CALCulate:MARKer:FIXed 1
Front Panel
Access: Marker, More, Marker Style (Fixed)