VNA Commands :CALCulate:MARKer Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 3-53
3-8 :CALCulate:MARKer Subsystem
This subsystem contains commands to manipulate data markers.
Turn All Markers Off
:CALCulate:MARKer:AOFF
Turns off all markers. This command turns off all markers that are not currently set to off.
Marker Data
:CALCulate:MARKer:DATA?
Description: Reports the marker information. Each marker data is separated by a
comma and data are returned similar to that when Readout Format is
set to Table.
Syntax: :CALCulate:MARKer:DATA?
Cmd Parameter: NA (query only)
Query Response: <char> (comma separated data)
Front Panel
Access: NA