:MMEMory:STORe Subsystem Vector Voltmeter Commands
4-6 PN: 10580-00306 Rev. E MS20xxC PM
4-5 :MMEMory:STORe Subsystem
The Mass MEMory STORe subsystem contains commands to transfer from the internal
memory to the mass memory device.
Save Setup
:MMEMory:STORe:STATe
Description: Stores the current setup into the file that is specified by14
<file name>. <file name> must be enclosed in either single
quotes (‘ ’) or double quotes (“ ”) and must not contain a file extension.
The <integer> is used to distinguish whether the calibration should
be saving with the setup. Send a 1 to save setup without a calibration.
Send a 2 to save setup with calibration.
Syntax: :MMEMory:STORe:STATe <integer>,<file name>
Cmd Parameter: <integer>,<string> (1|2, filename)
Query Response: NA (no query)
Front Panel
Access: NA