:MMEMory:MSIS Subsystem All Mode Commands
8-8 PN: 10580-00306 Rev. E MS20xxC PM
Copy to Destination
:MMEMory:MSIS:DESTination
Description: Sets the destination to where measurements and setups in the current
storage location are to be copied.
Setting the location to INTernal copies the files that are stored at the
current storage location into the internal memory when the command
:MMEMory:MSIS:COPY is sent.
Setting the location to USB copies the files that are stored at the
current storage location into the USB Flash drive when the command
:MMEMory:MSIS:COPY is sent.
Note that the storage location can be set independently and can be
different for remote operation and front panel operation. Changing the
save location remotely does not change the location that is set and
displayed on the front panel. Similarly, changing the save location via
the front panel does not affect the location that is used by the remote
operation commands.
Syntax: :MMEMory:MSIS:DESTination INTernal|USB
:MMEMory:MSIS:DESTination?
Cmd Parameter: <char> INTernal|USB
Query Response: <char> INT|USB
Related Command: :MMEMory:MSIS
:MMEMory:MSIS:COPY
Front Panel
Access: Shift-7 (File), Copy, Scroll Destination Folder, Select or De-Select