:CALCulate:LIMit Subsystem VNA Commands
3-28 PN: 10580-00306 Rev. E MS20xxC PM
Lower Limit Point X Value (continued)
Example: To set the trace 4 lower limit point to 5000 Hertz (trace 4 in frequency
domain):
:CALCulate4:LIMit:LOWer:POINt:X 5000
OR to 500 MHz:
:CALCulate4:LIMit:LOWer:POINt:X 500 MHz
To set the trace 1 lower limit point to 5 Feet (trace 1 in distance domain
with current distance unit in meter):
:CALCulate:LIMit:LOWer:POINt:X 5 FT
OR to 4 Meter
:CALCulate1:LIMit:LOWer:POINt:X 4 M
OR to 4 Meter
:CALCulate:LIMit:LOWer:POINt:X 4
To set the trace 2 lower limit point to 2.5 nanoseconds (trace 2 in time
domain):
:CALCulate2:LIMit:LOWer:POINt:X 2.5 ns
To set the trace 3 lower limit point to 25 us (trace 3 in time domain):
:CALC3:LIM:LOW:POIN:X 25 us
Related Command: :CALCulate:LIMit:TYPE
[:SENSe]:TRACe<Tr>:DOMain
[:SENSe]:TRACe<Tr>:SELect
Front Panel
Access: Shift 6 (Limit), Limit Edit, Limit X