EasyManua.ls Logo

Anritsu MS2026C - 3-23 [:Sense]:Correction Subsystem; Error Correction Data

Anritsu MS2026C
410 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VNA Commands [:SENSe]:CORRection Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 3-105
3-23 [:SENSe]:CORRection Subsystem
This subsystem provides commands for losses or gains external to the instrument.
Error Correction Data
[:SENSe]:CORRection:DATA?
Title: Error Correction Data
Description: Transfers the system error correction data from the instrument to the
controller. <error term parameter> are string parameters that
describe the different error terms.
Table 3-6. [:SENSe]:CORRection Subsystem
Keyword Parameter Data or Units
[:SENSe]
:CORRection
:CKIT Refer to “[:SENSe]:CORRection:CKIT Subsystem” on page 3-108
:COLLect Refer to “[:SENSe]:CORRection:COLLect Subsystem” on page 3-118
<error term parameter> Descriptions
ERF (Forward) Reflection tracking
EDF (Forward) Directivity
ESF (Forward) Source match
ETF (Forward) Transmission tracking
ELF (Forward) Load match
EXF (Forward) Isolation
ETFS (Forward Sensitivity) Transmission tracking
ELFS (Forward Sensitivity) Load match
EXFS (Forward Sensitivity) Isolation
ERR (Reverse) Reflection tracking
EDR (Reverse) Directivity
ESR (Reverse) Source match
ETR (Reverse) Transmission tracking
ELR (Reverse) Load match
EXR (Reverse) Isolation
ETRS (Reverse Sensitivity) Transmission tracking
ELRS (Reverse Sensitivity) Load match
EXRS (Reverse Sensitivity) Isolation