[:SENSe]:CORRection Subsystem VNA Commands
3-106 PN: 10580-00306 Rev. E MS20xxC PM
Error Correction Data (continued)
The format of the block data that is returned can be specified by the
command :FORMat:DATA. The response begins with an ASCII header
that specifies the number of data bytes. It appears in the format #AX,
where A is the number of digits in X, and X is the number of bytes
that follow the header. Each data point is separated by a comma
delimiter. Each term contains one complex value (real and imaginary)
for each sweep point.
Syntax: [:SENSe]:CORRection:DATA? <error terms parameters>
Cmd Parameter: NA (query only)
Query Response: <char> (returns block data)
Related Command: :FORMat:DATA
Front Panel
Access: NA
Smith Chart Reference Impedance
[:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude]:SMCHart
Description: Sets the Smith Chart reference impedance. Sets 50 for 50 ohm. Sets
75 for 75 ohm. The query form of the command returns the current
Smith Chart reference impedance in ohms.
Syntax: [:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude]
:SMCHart 50|75
[:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude]
:SMCHart?
Cmd Parameter: <char> 50|75
Query Response: <char> 50|75
Range: 50 ohm, 75 ohm
Default Value: 50 ohm
Front Panel
Access: Scale, Reference Impedance
Note
The Reference Admittance that is used in the Inverse Smith Chart graph type and
in the Admittance marker readout is the inverse of this Reference Impedance value
and is derived from this variable.