EasyManua.ls Logo

Anritsu MS2026C - DUT User Cutoff Frequency; DUT User Name

Anritsu MS2026C
410 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VNA Commands [:SENSe]:CORRection:CKIT:USER Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 3-115
DUT User Cutoff Frequency
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:WGUide:SSLT|SSST
:FCUToff
Description: Sets the DUT cutoff frequency for the specified user.
Syntax: [:SENSe]:CORRection:CKIT:USER[1]|2|3|4:WGUide:SSLT|SSST
:FCUToff <freq>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:WGUide:SSLT|SSST
:FCUToff?
Cmd Parameter: <NRf> <freq> (hertz)
Query Response: <NR3> <freq> (hertz)
Default Unit: Hz
Range: 5 kHz to 20 GHz for MS2028C, MS2038C
5 kHz to 15 GHz for MS2027C, MS2037C
5 kHz to 6 GHz for MS2026C, MS2036C
Example: To set the DUT cutoff frequency for User 1 with calibration method
SSLT to 1 GHz:
:SENS:CORR:CKIT:USER:WGU:SSLT:FCUT 1GHz
Front Panel
Access: NA
DUT User Name
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX|WGUide
:SOLT|SSLT|SSST:NAME
Description: Sets the DUT name for the specified user.
Syntax: [:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX|WGUide
:SOLT|SSLT|SSST:NAME <string>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX|WGUide
:SOLT|SSLT|SSST:NAME?
Cmd Parameter: <string> (no parameter data or units)
Query Response: <string> (no parameter data or units)
Example: To set the DUT name for User 1 with line type coax and calibration
method SOLT:
:SENS:CORR:CKIT:USER:COAX:SOLT:NAME “SOLT1”
Front Panel
Access: NA

Table of Contents

Related product manuals