:TRACe Subsystem Spectrum Analyzer Commands
6-60 PN: 10580-00306 Rev. E MS20xxC PM
Trace View State
:TRACe{1|2|3}:DISPlay[:STATe]
Description: Specifies whether the designated trace should be displayable (visible) or
hidden. TRACe1 corresponds to Trace A, TRACe2 corresponds to
Trace B, and TRACe3 corresponds to Trace C. Setting the value to ON
or to 1 sets the designated trace to be visible. Setting the value to OFF
or to 0 sets the designated trace to be hidden. Note that issuing this
command also sets the specified trace as the active trace.
Syntax: :TRACe{1|2|3}:DISPlay[:STATe] OFF|ON|0|1
:TRACe{1|2|3}:DISPlay[:STATe]?
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: ON for Trace A
OFF for Trace B
OFF for Trace C
Example: To set Trace A to Blank:
:TRACe:DISPlay OFF
:TRACe1:DISPlay 0
To set Trace B to View:
:TRACe2:DISPlay ON
:TRACe2:DISPlay:STATe ON
:TRACe2:DISPlay 1
Front Panel
Access: Shift-5 (Trace), View/Blank