EasyManua.ls Logo

Anritsu MS2026C - Center Frequency; Channel Selection

Anritsu MS2026C
410 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectrum Analyzer Commands [:SENSe] Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 6-79
Center Frequency
[:SENSe]:FREQuency:CENTer
Description: Sets the center frequency. Note that changing the value of the center
frequency changes the value of the coupled parameters: Start
Frequency and Stop Frequency. It may also change the value of the
span.
Syntax: [:SENSe]:FREQuency:CENTer <freq>
[:SENSe]:FREQuency:CENTer?
Cmd Parameter: <freq>
Query Response: <freq>
Range: 0 Hz and 10 Hz to 9 GHz for MS2036C
0 Hz and 10 Hz to 15 GHz for MS2037C
0 Hz and 10 Hz to 20 GHz for MS2038C
Default Unit: Hz
Default Value: 4.5 GHz for MS2036C
7.5 GHz for MS2037C
10 GHz for MS2038C
Front Panel
Access: Freq, Center Freq
Channel Selection
[:SENSe]:FREQuency:SIGStandard:CHANnel
Description: Sets the channel number for the selected signal standard.
Parameter: <number>
Syntax: [:SENSe]:FREQuency:SIGStandard:CHANnel <number>
[:SENSe]:FREQuency:SIGStandard:CHANnel?
Cmd Parameter: <number>
Query Response: <number>
Front Panel
Access: Freq, Channel

Table of Contents