7 BACnet Communication
3-126 WindO/I-NV4 User’s Manual
Analog Output Object
This object manages a Float32(F) numeric value. The MICRO/I can receive arbitrary numeric values from BACnet
devices. For example, this object is used when receiving analog values such as those values that are output with the
analog output module and temperature set points used as operating parameters from BACnet devices.
Properties List
(1): Read and write from BACnet devices
(2): Read and write from device addresses when properties are allocated to device addresses
R: Read-only, W: Write-only, R/W: Read and write, -: Not Read and write
*1 Character encoding is ISO 10646 (UTF-8), and the maximum size is 64 bytes.
*2 Cannot be displayed on WindO/I-NV4.
Property Identifier Data Type of Property (1) (2) Comments
Object_Identifier BACnetObjectIdentifier R - Set a fixed value with WindO/I-NV4.
Object_Name
Character string
*1
R - Set a fixed value with WindO/I-NV4.
Object_Type BACnetObjectType R - Set a fixed value with WindO/I-NV4.
Present_Value Real number R R Refer to “Present_Value” on page 3-132.
Description
Character string
*1
R - Set a fixed value with WindO/I-NV4.
Device_Type
Character string
*1
R - Set a fixed value with WindO/I-NV4.
Status_Flags BACnetStatus_Flags R R Refer to “Status_Flags” on page 3-145.
Event_State BACnetEventState R - Normal (fixed).
Reliability BACnetReliability R R/W
Indicates whether or not the value of
Present_Value is reliable.
Out_Of_Service Logical value R/W R/W Refer to “Out_Of_Service” on page 3-146.
Units BACnetEngineeringUnits R/W - Set the initial value with WindO/I-NV4.
Resolution Real number R - Set a fixed value with WindO/I-NV4.
Priority_Array BACnetPriority_Array R/W - Refer to “Priority_Array” on page 3-145.
Relinquish_Default Real number R/W - Refer to “Relinquish_Default” on page 3-145.
COV_Increment Real number R/W - Refer to “COV_Increment” on page 3-145.
Property_List
*2
BACnetARRAY[N] of type
BACnetPropertyIdentifier
R - Cannot be edited with WindO/I-NV4.