11 Calendar
10
Data Displays
Day of the Week Settings
Configures the content to be displayed as the day of the week. These options can only be configured when Clock or
Clock & Alarm is selected for Calendar Type and Date & Day of the Week & Time, Date & Day of the Week,
Time & Date & Day of the Week, Time & Day of the Week, Day of the Week & Time or Day of the Week is
selected for Clock Type.
Alarm Tab
These options can only be configured when Alarm or Clock & Alarm is selected for Calendar Type on the
General tab.
Alarm Time
Selects the type of data for the alarm time.
Type: Selects the string to indicate the day of the week from the following:
( ), ( ), ..., ( ), Sun., Mon., ..., Sat., Sunday, Monday, ..., Saturday,
星期日 , 期一 , ..., 星期六 , Customize
When Customize is selected, configures the string to indicate the day of the week. The maximum
number is 10 characters.
(Alarm conditions)
Value: Specifies the alarm time as values and the day of the week.
Year: Enter the year (0 to 99).
Month: Enter the month (1 to 12).
Day: Enter the day (1 to 31).
Day of the Week: Select the day of the week.
Hour: Enter the hour (0 to 23).
Minute: Enter the minute (0 to 59).
Second: Enter the second (0 to 59).
Device Address: Configures the alarm time as values of word devices.
It handles as a value whose data type is BCD4(B). Configures the year, month, day, hour, minute, and
second values in the same range as Value. Specifies the day of the week with the following values.
0: Sunday, 1: Monday, 2: Tuesday, 3: Wednesday, 4: Thursday, 5: Friday, 6: Saturday
Click to display the Tag Editor. For the device address configuration procedure, refer to Chapter
2 “5.1 Device Address Settingson page 2-70.
If the data of the alarm time is invalid, 1 is written to System Area 2 Processing error bit (address
number+2, bit 5), and an error message is displayed. For details, refer to Chapter 4 “Processing error” on
page 4-32 and Chapter 36 “Processing error” on page 36-3.
An error occurs in the following states:
Year, Month, Day, Hour, Minute or Second are set to values outside the range of Value.
A value outside the range of BCD4(B) is entered.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC WindO/I-NV4 and is the answer not in the manual?

IDEC WindO/I-NV4 Specifications

General IconGeneral
BrandIDEC
ModelWindO/I-NV4
CategoryOrganizer
LanguageEnglish