1 - 102 Code Restriction Class Assignment when Lockout is Set
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-1-70
System Mode
1
Submode
1
Data No.
70
PC Programming
a
+AC
Code Restriction Class Assignment
when Lockout is Set
General Description
Use this Memory Block to assign the Code Restriction Class when a station user sets the
Station Lockout or when the Attendant sets Attendant Station Lockout.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 + GK to access the Memory Block.
3 Used dial pad to enter class restriction.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~Ito enter numeric data
Default Values
Class 01
4 Press
Nto write selected data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Section 6 Code Restriction in this chapter.
N
When a station is locked out, the Code Restriction Class Assignment of this Memory Block is used instead of the Code
Restriction Class assigned in Memory Block 4-07, Code Restriction Class Assignment (Day Mode) or 4-08, Code
Restriction Class Assignment (Night Mode).
7 0 : R E S T C L A S S = 0 1
T I M E D I S P L A Y
Data
No.
Title
1~7
Setting
Data