First Digit PBR Release Timer Selection 1 - 139
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-3-03
System Mode
1
Submode
3
Data No.
03
PC Programming
a
+BTI
First Digit PBR Release Timer
Selection
General Description
Use this Memory Block to specify how long a Push Button Receiver (PBR) receiver circuit is
connected when a dual-tone multifrequency (DTMF) Single Line Telephone user goes off-
hook. After the timer expires the PBR is disconnected. If the Single Line Telephone user
dials a digit before the timer expires, a PBR interdigit timer starts.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates the default setting.
10 sec. 20 sec. 30 sec. 40 sec.
LK 5 LK 6 LK 7 LK 8
50 sec. 60 sec.
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 + KC to access the Memory Block.
3 Press the corresponding CO/PBX line key to change data option.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-8-10
PBR Interdigit Release Timer Selection
4-93
DTMF/DP SLT Type Selection
0 3 : P B R R L S 1 0 s
T I M E D I S P L A Y
Setting
Data
Title
Data
No.

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals