EasyManua.ls Logo

NEC Xen Master - 3-17 Tie Line Answer Detect Time Selection

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tie Line Answer Detect Time Selection 1 - 275
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
3-17
System Mode
3
Submode
Data No.
17
PC Programming
a
+ALM
Tie Line Answer Detect Time
Selection
General Description
Use this Memory Block to specify the duration between the time when the receiving Xen
system answers (off-hook) and the time when it is recognized as an answer.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3
LK 4
The shaded area indicates the default setting.
0 ms. 130 ms. 260 ms. 390 ms.
LK 5 LK 6 LK 7 LK 8
520 ms. 650 ms. 780 ms. 910 ms.
(Page 2)
LK 1LK 2LK 3LK 4
1040 ms. 1170 ms. 1300 ms. 1430 ms.
LK 5 LK 6 LK 7 LK 8
1560 ms. 1690 ms. 1820 ms. 1950 ms.
Programming Procedures
1 Go off-line.
2 Press LK3 +
N + AG to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note: The following are used when entering data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. Answering a call may not be possible if the CO answer detect time is too long.
0 1 / 1 7 : P R E 3 9 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.

Table of Contents

Other manuals for NEC Xen Master