External Speaker Connection Selection 1 - 183
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-7-02
System Mode
1
Submode
7
Data No.
02
PC Programming
a
+BP
External Speaker Connection
Selection
General Description
Use this Memory Block to specify whether or not external speakers are connected to the
system.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
ESP A ESP B ESP C
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK7 +
KB to access the Memory Block.
3 Press the CO/PBX line key corresponding to each ESP Zone. The LED changes to indicate the data each time the CPO/PBX line
key is pressed.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-7-03
External Paging Alert Zone Selection
N
Only three external speaker zones can be connected to the system.
0 2 : E S P C O N N
T I M E D I S P L A Y
Data
No.
Title
CO/PBX
Line LED
Off On
Data No Yes
There is no default setting.