1 - 166 Automated Attendant Delay Announcement Disconnect Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-4-20
System Mode
1
Submode
4
Data No.
20
PC Programming
a
+AU
Automated Attendant Delay
Announcement Disconnect Time
Selection
General Description
Use this Memory Block to establish how long the Automated Attendant rings the stations
before disconnecting the caller. This Memory Block only applies when the Automated
Attendant is set to the Delay Announcement Mode.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
Immediate
(0s)
10 sec.
(10s)
20 sec.
(20s)
30 sec.
(30s)
LK 5 LK 6 LK 7 LK 8
1 min.
(1m)
2 min.
(2m)
3 min.
(3m)
4 min.
(4m)
LK9 LK10 LK11 LK12
5 min.
(5m)
10 min.
(10m)
20 min.
(20m)
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
BKto access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Example: To change 30 seconds to 10 seconds, press CO/PBX line key 2.
Default Values
Specified in the shaded area.
4 Press
N to write the selected data and advance to Memory Block 1-5-02 SMDR Print Format.
5 Press
P to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-4-18
Automated Attendant Delay Announcement Assignment
1-4-19
Automated Attendant 1
st
to 2
nd
Delay Announcement Interval Time Selection
2 0 : 2 n d I N T R V L 3 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data