Tandem Transfer Automatic Disconnect Timer Selection 1 - 147
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-4-00
System Mode
1
Submode
4
Data No.
00
PC Programming
a
+AT
Tandem Transfer Automatic
Disconnect Timer Selection
General Description
Use this Memory Block to specify maximum time before the system automatically
disconnects a Trunk-to-Trunk connection.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
30 min. 1 hr. 2 hr. 3 hr.
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
KK to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data
option or enter the time required in minutes
Default Values
060 min
Setting Data
000~999 (Software Version 2.xx or later)
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2 Guide to Feature Programming
N
This block is used for Direct Inward System Access (DISA), Trunk-to-Trunk Transfer, Call Forward - Off Premise, and Tie
line tandem features.
0 0 : A U T O D I S 0 6 0
T I M E D I S P L A Y
Data
No. Title
Setting
Data

Table of Contents