Automated Attendant Delay Announcement Hold Tone Selection 1 - 163
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-4-17
System Mode
1
Submode
4
Data No.
17
PC Programming
a
+AU
Automated Attendant Delay
Announcement Hold Tone Selection
General Description
Use this Memory Block to specify the tone that is sent to the outside party after the
Automated Attendant Delay Announcements are played.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
RBT MOH
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
AGto access the Memory Block.
3 Press the corresponding CO/PBX line to change data option.
Example: To change RBT to MOH, press CO/PBX line key 2.
Default Values
All Messages One Time
4 Press
Nto write the data and advance to Memory Block 1-4-18 Automated Attendant Delay Announcement Assignment
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-4-18
Automated Attendant Delay Announcement Assignment
1-4-19
Automated Attendant 1
st
to 2
nd
Delay Announcement Interval Time Selection
1-4-20
Automated Attendant Delay Announcement Disconnect Time Selection
1 7 : A A H O L D R B T
T I M E D I S P L A Y
Data
No.
Title
Setting
Data