Master Clock Selection 1 - 221
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-8-33
System Mode
1
Submode
8
Data No.
33
PC Programming
a
+AN
Master Clock Selection
General Description
When either a PRT(1)-U13 or BRT(4)-U13 ETU is installed, clocking must be synchronized.
This Memory Block assigns the source to be synchronized with. Enter the cabinet/slot
number of the PRT or BRT ETU to be used for synchronization of the CLKG-U13. This
synchronised clock signal is then fed to each of the remaining BRT and PRT ETUs.
Note: If the master clock selection is changed, all PRT traffic is dropped immediately as the
resynchronisation occurs.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK8 +
CC to access the Memory Block.
3 Use dial pad to enter number of digits.
Note: Use the following to enter data:
K~I to enter digits
J to move cursor left
L to move cursor right
Default Values
Cabinet 0 (Not Assigned)
Setting Data
Cabinet 0 ~ 3
Slot 1 ~ 8
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1
Card Interface Slot Assignment
N
1. The PRT and BRT ETUs must only be installed in the first or second cabinet.
2. When a PRT or BRT ETU is installed, a CLSG-U13 Unit must be fitted to the CPUB( )-U13 ETU/MBD-U13 KSU.
3. Ensure this Memory Block is set correctly when a BRI or PRI card is installed.
4. If Clock is not set, data services via ISDN may be affected.
3 3 : M S T T C L C K 0 :
T I M E D I S P L A Y
Data
No.
Title
Cabinet
0~3
Slot 1~8