Loading...
1 - 182 Doorphone Display Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-7-01
System Mode
1
Submode
7
Data No.
01
PC Programming
a
+BTP
Doorphone Display Time Selection
General Description
Use this Memory Block to define how long a doorphone call signals a station before it times
out.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
10 sec. 30 sec. 60 sec. 90 sec.
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK7 +
KA to access the Memory Block.
3 Press the CO/PBX line key corresponding to each time assignment. The LED changes to indicate the data each time the CO/PBX
line key is pressed.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-7-00
Doorphone Assignment
0 1 : D P H T I M E R 1 0 s