EasyManuals Logo

NEC Xen Master Programming Manual

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #200 background imageLoading...
Page #200 background image
1 - 182 Doorphone Display Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-7-01
System Mode
1
Submode
7
Data No.
01
PC Programming
a
+BTP
Doorphone Display Time Selection
General Description
Use this Memory Block to define how long a doorphone call signals a station before it times
out.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
10 sec. 30 sec. 60 sec. 90 sec.
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK7 +
KA to access the Memory Block.
3 Press the CO/PBX line key corresponding to each time assignment. The LED changes to indicate the data each time the CO/PBX
line key is pressed.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-7-00
Doorphone Assignment
0 1 : D P H T I M E R 1 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals