Start Timer Selection 1 - 35
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-1-05
System Mode
1
Submode
1
Data No.
05
PC Programming
a
+BM
Start Timer Selection
General Description
Use this Memory Block to specify the time needed after dialling before the system starts the
Elapsed Call Timer, SMDR Start Timer, and Talk Start Timer.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
10 sec. 20 sec. 30 sec. 40 sec.
LK 5 LK 6 LK 7 LK 8
50 sec. 60 sec. 70 sec. 2 sec.
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 + KE to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-5-25
SMDR Valid Call Timer Assignment
N
This timer is used for three different features with functions described below:
Elapsed Call Timer: The time needed after dialling until the Elapsed Call Timer is started and displayed on a Multiline
Terminal.
SMDR Start Timer: The time needed after dialling until the SMDR Valid Call Timer is started. Refer to Memory Block
1-5-25 SMDR Valid Call Timer Assignment. For outgoing calls, both timers (SMDR Start Timer and
SMDR Valid Call Timer Assignment) must elapse before a call record is generated.
Lines set as “YES” in Memory Block 3-71, as having Reversal on Answer, do not follow this Memory Block.
0 5 : C A L L S T A R T 1 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals