SMDR Valid Call Timer Assignment 1 - 173
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-5-25
System Mode
1
Submode
5
Data No.
25
PC Programming
a
+AS
SMDR Valid Call Timer Assignment
General Description
Use this Memory Block to assign the minimum length of a call before the Station Message
Detail Recording (SMDR) outputs a record of the outgoing CO/PBX call.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK5 +
BEto access the Memory Block.
3 Use the dial pad to enter data.
 Minimum time assignment is 000 sec.
 Time assignment can be set from 000 sec.~990 sec. in increments of 10
(Setting Data: 00~99)
Default Values
0 seconds
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-05
Start Timer Selection
1-5-13
Printer Connected Selection
2 5 : S M D R T I M = 0 0 0 S
T I M E D I S P L A Y
Data
No. Title
Setting
Data

Table of Contents