1 - 34 Automatic Redial Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-1-04
System Mode
1
Submode
1
Data No.
04
PC Programming
a
+BM
Automatic Redial Time Selection
General Description
If a called party is busy, the station user dials an Access Code and restores the handset.
Use this Memory Block to define the redial timing parameters when automatic redial is set
to a busy CO/PBX number. After the specified number of call attempts with no answer, the
system stops dialling.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 + KD to access the Memory Block.
3 Use the dial pad to enter the Table Number and Setting Data.
Note: Use the following to enter data:
Jto move the cursor left
Lto move the cursor right
Setting Data (Allowed):
Table 1 (Calling Time): 001~050 sec.
Table 2 (Call Waiting Time): 001~100 sec.
Table 3 (Call Attempts): 001~009 times (3 digit input)
Note: 000 cannot be entered.
Default Values
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. Definitions:
Calling Time: The time that the system automatically calls the busy CO/PBX number. After the
specified time limit is reached, the call is abandoned.
Call Waiting Time: The time the system waits between call attempts.
Call Attempts: The number of times the system redials the busy CO/PBX number.
2. If Call Pickup Groups are assigned using Memory Block 4-09 Telephone to Tenant Assignment, the CO lines must be
assigned to the same Tenant Group in Memory Block 2-01 Trunk to Tenant Assignment for this feature to work.
0 4 : R E D I A L ( X ) 0 3 0
X = 1, 2, 3
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
Table
Table
No.
Description Value
1 Calling Time 30 sec.
2 Call Waiting Time 60 sec.
3 Call Attempts 2