6.3 Memory Blocks
The following related Memory Blocks are used when assigning Code Restriction.
6.4 Memory Block Description
6.4.1 General
This section describes the function of the Memory Blocks directly related to
Code Restriction. Some Memory Blocks from the previous list are not
described here but are included because of their effect on Code Restriction
(
e.g., Trunk to Tenant Assignment). Code Restriction is based on Trunk
group and consideration should be given to this Memory Block because
stations are assigned to a tenant, and trunks are assigned to a Trunk group.
6.4.2 OCC Assignment/Operation
OCC Table Assignment
(Memory Block 1-1-67)
This Memory Block allows an OCC Access Code (maximum of eight digits)
to be assigned. System Programming has 16 OCC Tables (01~16). Each
table can have one OCC Access Code assigned.
Title Memory Block
Trunk to Tenant Assignment 2-01
Trunk-to-Trunk Group Assignment 3-03
Trunk Type Selection 3-91
PBX/CTX Access Code Assignment I 1-1-24
PBX/CTX Access Code Assignment II 1-1-25
OCC Table Assignment 1-1-67
OCC Table to Trunk Group Assignment 5-03
8-Digit Matching Table to OCC Table Assignment 1-1-68
8-Digit Matching Table to Normal Dial Assignment 1-1-66
8-Digit Matching Table to Trunk Group Assignment 5-02
8-Digit Matching Table Assignment 1-1-60
8-Digit Matching Table to Class Assignment 1-1-61
Code Restriction Class Allow/Deny Assignment 1-1-65
System Speed Dial Restriction by Tenant 1-1-18
System Speed Dial Override by Class Selection 1-1-62
Tie Line Code Restriction Assignment 1-1-69
Code Restriction Class Assignment When Lockout is Set 1-1-70
CO Feature Codes Service for Code Restriction 1-1-82
Trunk Digit Restriction 4-32
Code Restriction Class Assignment (Day Mode) 4-07
Code Restriction Class Assignment (Night Mode) 4-08
Telephone to Tenant Assignment 4-09

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals