Page #51 background image
Hold Recall Timer Selection (Non-Exclusive Hold) 1 - 33
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-1-03
System Mode
1
Submode
1
Data No.
03
PC Programming
a
+BM
Hold Recall Timer Selection (Non-
Exclusive Hold)
General Description
Use this Memory Block to specify the time a Non-Exclusive Hold outside call is held until a
recall tone is generated. If No Limit is selected, the hold recall alarm tone is not generated.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
25 sec. 45 sec. 60 sec. 90 sec.
LK 5 LK 6 LK 7 LK 8
120 sec. 180 sec. 240 sec. No Limit
Related Programming
M.B. Number Memory Block Name
1-1-63
Hold Recall Time Selection (Exclusive)
1-2-23
System Call Park Recall Time Selection
N
1. Calls put on Exclusive Hold, recall using the data selected in Memory Block 1-1-63 Hold Recall Time Selection
(Exclusive).
2. Calls placed on hold on Call Appearance keys, recall using this Memory Block.
3. Calls parked in System Call Park locations recall using Memory Block 1-2-23 System Call Park Recall Time
Selection.
0 3 : H O L D R E C L 6 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals