Hookflash Start Time Selection 1 - 141
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-3-05
System Mode
1
Submode
3
Data No.
05
PC Programming
a
+BTI
Hookflash Start Time Selection
General Description
Use this Memory Block to specify the minimum hookflash duration from Single Line
Telephone.
Display
Settings
(Page 1)
LK 1LK 2LK 3LK 4
The shaded area indicates the default setting.
40 ms. 90 ms. 140 ms. 190 ms.
LK 5 LK 6 LK 7 LK 8
240 ms. 290 ms. 340 ms. 390 ms.
(Page 2)
LK 1LK 2LK 3LK 4
440 ms. 490 ms. 540 ms. 590 ms.
LK 5 LK 6 LK 7 LK 8
640 ms. 690 ms. 740 ms. 790 ms.
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3 +
KE to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 PressNto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-3-01
Bounce Protect Time Selection
1-3-06
Hookflash End Time Selection
N
1. Press hookswitch during CO/PBX call to place the line on hold or send hookflash to CO/PBX.
2. Bounce Protect Time [Memory Block 1-3-01 Bounce Protect Time Selection] and Hookflash Start Time must be
equal.
0 5 : F L S H S T 4 0 | 1
T I M E D I S P L A Y
Setting
Data
Title
Data
No.
Page
No.