NEC Xen Master - 3-41 ACD;UCD Delay Announcement Assignment

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACD/UCD Delay Announcement Assignment 1 - 299
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
3-41
System Mode
3
Submode
Data No.
41
PC Programming
a
+AR
ACD/UCD Delay Announcement
Assignment
General Description
Use this Memory Block to specify, per CO Port, whether or not ACD/UCD Delay
Announcement is sent to the calling party for Day and/or Night Mode.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates the default setting.
NN YN NY YY
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK3 +
N + DAto access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
R to go to the next CO/PPBX Line No.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2 Guide to Feature Programming
0 1 / 4 1 : M S G D / N = N N
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Setting
Data
Title
Data
No.
Setting Data:
Line
Key
LCD
Indication
ACD/UCD Delay
Announcement
1NN No
2YN Day Only
3 NY Night Only
4 YY Day and Night