EasyManua.ls Logo

NEC Xen Master - 3-16 Tie Line Prepause Time Selection

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 - 274 Tie Line Prepause Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
3-16
System Mode
3
Submode
Data No.
16
PC Programming
a
+ALM
Tie Line Prepause Time Selection
General Description
Use this Memory Block to specify the time (prepause) when the originating side becomes
able to send dial pulse or dual-tone multi-frequency (DTMF) to the distant system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
0 sec. 0.5 sec. 1.0 sec. 1.5 sec.
LK 5 LK 6 LK 7 LK 8
2.0 sec. 3.0 sec. 4.0 sec. 5.0 sec.
(Page 2)
LK 1 LK 2 LK 3 LK 4
6.0 sec. 7.0 sec. 8.0 sec. 9.0 sec.
LK 5 LK 6 LK 7 LK 8
10.0 sec. 11.0 sec. 12.0 sec. 13.0 sec.
Programming Procedures
1 Go off-line.
2 Press LK3 +
N + AF to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note: The following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. Prepause time differs according to the acknowledgment signaling method.
0 1 / 1 6 : P R E 0 | 1