1 - 274 Tie Line Prepause Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
3-16
System Mode
3
Submode
—
Data No.
16
PC Programming
a
+ALM
Tie Line Prepause Time Selection
General Description
Use this Memory Block to specify the time (prepause) when the originating side becomes
able to send dial pulse or dual-tone multi-frequency (DTMF) to the distant system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
0 sec. 0.5 sec. 1.0 sec. 1.5 sec.
LK 5 LK 6 LK 7 LK 8
2.0 sec. 3.0 sec. 4.0 sec. 5.0 sec.
(Page 2)
LK 1 LK 2 LK 3 LK 4
6.0 sec. 7.0 sec. 8.0 sec. 9.0 sec.
LK 5 LK 6 LK 7 LK 8
10.0 sec. 11.0 sec. 12.0 sec. 13.0 sec.
Programming Procedures
1 Go off-line.
2 Press LK3 +
N + AF to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note: The following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. Prepause time differs according to the acknowledgment signaling method.
0 1 / 1 6 : P R E 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.