EasyManua.ls Logo

NEC Xen Master - 3-67 CO Line Ringing Pattern Selection for CO;PBX Line Mode

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIT Night Mode Delay Answer Enable 1 - 313
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
3-67
System Mode
3
Submode
Data No.
67
PC Programming
a
+BCT
CO Line Ringing Pattern Selection for
CO/PBX Line Mode
General Description
Use this Memory Block to specify the ring pattern for incoming calls or CO lines.
Display
Settings
(Page 1)
LK 1LK 2LK 3LK 4
The shaded area indicates the default setting.
—A B C
LK 5 LK 6 LK 7 LK 8
DEFG
(Page 2)
LK 1LK 2LK 3LK 4
H
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK3 +
N + FG to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
Note: The following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
Default Values
— = NON
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
4-53
CO Ringing Pattern Selection for Telephone Mode
4-56
CO Line Ringing Pattern by Telephone or CO Selection
0 1 / 6 7 : C O R N G | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.