3-Minute Alarm Selection 1 - 387
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
4-94
System Mode
4
Submode
—
Data No.
94
PC Programming
a
+BTM
3-Minute Alarm Selection
General Description
Use this Memory Block to specify, per station, whether or not a warning signal tone is
generated at 3-minute intervals during an outgoing or incoming CO/PBX call.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates the default setting.
No Ys
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK4 +
ID to access the Memory Block.
3 Press the corresponding CO/PBX line key to change data option.
Note: Use the following to change option:
R select next Tel Port No.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. A 1-second (approximately) warning signal sounds every 3 minutes during CO/PBX calls.
2. The alarm tone is heard through the terminal speaker only.
3. If the built-in speakerphone is used for Handsfree, the warning signal is not used.
4. Telephone ports A0~C0 are ports 100~120.
0 1 / 9 4 : 3 m A L M N O
T I M E D I S P L A Y
Data
No.
Tel Port No.
(01~99)
A0~C0
Title
Setting
Data