1 - 30 DP Interdigit Time Selection
NEC Business Solutions Ltd Xen Master & Xen Axis
A6-324000-642-02 - Release 6.0
May 2003
1-1-01
System Mode
1
Submode
1
Data No.
01
PC Programming
a
+BCM
DP Interdigit Time Selection
General Description
The DP Interdigit Time is the minimum pause time interval between Dial Pulse dialling. Use
this Memory Block to Select either Pattern A or Pattern B
New Zealand - DP for COI/D is not allowed.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
Pattern A Pattern B
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1
+KAto access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
N
Use this Memory Block when CO/PBX or Tie lines are assigned in Memory Block 3-91 Trunk (Installed, DP/DTMF)
Selection, to send Dial Pulse signalling.
0 1 : D P I N T E R B
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
DP Dial
Data
10 pps 20 pps
Pattern A 650 ms. 500 ms.
Pattern B 800 ms. 800 ms.
Dial
Minimum
Pause
Time
Signal
Dial
Signal

Table of Contents