EasyManua.ls Logo

NEC Xen Master - 1-1-75 Second Delay Announcement Repeat Interval Time Selection

NEC Xen Master
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Second Delay Announcement Repeat Interval Time Selection 1 - 107
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-1-75
System Mode
1
Submode
1
Data No.
75
PC Programming
a
+AR
Second Delay Announcement Repeat
Interval Time Selection
General Description
Use this Memory Block to specify the interval time to repeat Second Delay Announcement
to the calling party.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
0 sec. 10 sec. 20 sec. 30 sec.
LK 5 LK 6 LK 7 LK 8
40 sec. 50 sec. 60 sec. No Limit
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
GE to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-73
First to Second Delay Announcement Interval Time Selection
1-1-74
Second Delay Announcement Repeat Selection
3-41
ACD/UCD Delay Announcement Assignment
N
This Memory Block does not display unless the MIFA-U13 ETU is installed.
7 5 : M S G 2 R P E T = 2 0 s
T I M E D I S P L A Y
Data
No.
Setting
Data
Title

Table of Contents