ID Restriction Class Assignment (Night Mode) 1 - 233
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-9-04
System Mode
1
Submode
9
Data No.
04
PC Programming
a
+BO
ID Restriction Class Assignment
(Night Mode)
General Description
Use this Memory Block to specify the NIGHT mode code restriction classes for each
ID number.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 + LK9 +
KD to access the Memory Block.
3 Use the dial pad to enter the data.
Setting Data:
Code Restriction Class 00 ~ 15
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~I to enter numeric data
R to access the next ID buffer number
Q+1, 2, 3 = A, B, or C for Port Number
ID Buffer Number:
01~99 = 01~99
A0~A9 = 100~109
B0~B9 = 110~119
C0 = 120
Default Values
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-19
Line Selection for Automatic Outgoing Calls
1-1-46
DID Digit Length Selection
1-1-47
DID Digit Conversion Assignment
1-1-48
DID Forward Station Number for Undefined Digit
* * 1-5-23 * *
T.B.A.
1-9-00
DISA/ID Code Assignment
1-9-02
DISA/ID Password Effect/Invalid Selection
1-9-03
ID Restriction Class Assignment (Day Mode)
0 1 / 0 4 : C L S N T = 0 0
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
ID Buffer No.
(01~96)
ID Buffer No. 01~120 = Code
Restriction Class No.00