Bounce Protect Time Selection 1 - 137
Programming Manual May 2003
A6-324000-642-02 - Release 6.0
May 2003
1-3-01
System Mode
1
Submode
3
Data No.
01
PC Programming
a
+BTI
Bounce Protect Time Selection
General Description
Use this Memory Block to specify the time before a valid hookflash is detected from a
Single Line Telephone or Voice Mail system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3
LK 4
The shaded area indicates the default setting.
0 ms. 100 ms. 200 ms. 300 ms.
LK 5 LK 6 LK 7 LK 8
400 ms. 500 ms. 600 ms. 700 ms.
(Page 2)
LK 1LK 2LK 3LK 4
800 ms. 900 ms. 1000 ms. 1100 ms.
LK 5 LK 6 LK 7 LK 8
1200 ms. 1300 ms. 1400 ms. 1500 ms.
Programming Procedures
1 Go off-line.
2 Press LK1 + LK3 +
KA to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-3-05
Hookflash Start Time Selection
N
Bounce Protect Time should be equal to Hookflash Start Time in Memory Block 1-3-05 Hookflash Start Time Selection.
0 1 : B N C E 3 0 0 m s | 1
T I M E D I S P L A Y
Page
No.
Setting
Data
Title
Data
No.