Programming Manual May 2003
Tie Line Release Detect Time Selection 1 - 277
A6-324000-642-02 - Release 6.0
May 2003
N
1. Specify distinguishing circuit release from on-hook, noise, and temporary interruption. There are four probable
situations for Tie line release detection:

Called side hangs up first. The circuit is released 92 ms. + specified time after the other party disconnects the call.
 Called side hangs up second. The circuit is released when the specified time has elapsed after the other party
hangs up.
 Originating side hangs up first. The circuit is released 92 ms. + specified time after the other party hangs up.
 Originating side hangs up second. The circuit is released when the specified time has elapsed after the other
party hangs up.