Programming Manual May 2003
Access Code (1-Digit) Assignment 1 - 69
A6-324000-642-02 - Release 6.0
May 2003
N
1. Select options from the list of function numbers in Memory Block 1-1-46 Access Code (1-Digit) Assignment, and
assign a number (from 0~9), , or # to each selected function.
• When a function is assigned a 1-digit Access Code, 2-digit Access Codes with the same first digit become
invalid (i.e., if a function is assigned to Access Code 5, Access Codes 50~59, 5, and 5# cannot be used.)
2. To enter # or  as part of an Access Code, press
Q then L or J.
3. This Memory Block is used when a 2- or 3-Digit Station Numbering Plan is programmed.
4. LCR must always use trunk group 1 Access Code.
5. When 4 digit extension numbering plan is used dial numbers 1~8 should be assigned as 000 (not used).
Assignment of extension number range is done in Memory Block 1-1-47, e.g. 1-1-46:
0 = 080 1~8 = 000
9 = 176
* = 095
# = 096
4 digit extension range required is 4000~4100
Memory Block 1-1-47
40 = 001 and 41 = 001.
It is then possible to use Memory Block 4-10 Station Number Assignment.
6. Call Forward Off Premise uses the same access codes as Internal Call Forward, however a Trunk Access Code is
entered instead of an Extension.
7. Version 1.xx of the system software supports Call Forward Off Premise on MLT and SLT extensions.
8. Version 2.xx of the system software supports Call Forward Off Premise on MLT, SLT and CAR keys.

Table of Contents

Other manuals for NEC Xen Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Xen Master and is the answer not in the manual?

NEC Xen Master Specifications

General IconGeneral
BrandNEC
ModelXen Master
CategoryTelephone
LanguageEnglish

Related product manuals