A.4
SEL-751 Relay Instruction Manual Date Code 20170927
Firmware, ICD, and Manual Versions
Firmware
Added Second- and Fifth-Harmonic Current Blocking (Inrush Current
Blocking) functionality.
Added fault impedance to the fault location information.
Increased the number of settings groups from 3 to 4.
Added Spanish language support on all communications ports. Also
added an ordering option for a relay with Spanish overlay and Spanish
front-panel HMI.
Added an ordering option for a 14 digital input card in Slots C, D, and E.
Added an ordering option for an 8 Arc-Flash Input card in Slot E.
Added LOP blocking functionality with the default value for LOPBLK
set to 0.
Added OFF to the 50 element, 50PnD, delay setting range.
Added torque-control settings for the frequency (81) and rate-of-
change-of-frequency (81R) elements with the default value set to 1.
Added COMTRADE Events support to the relay.
Added a feature in the CEV report to show the part number and serial
number of the relay.
Added unique reference numbering system for HIS, CHIS, SUM,
CSUM, EVE and CEV reports.
Added OFF to the setting range of failover time setting FTIME to
support fast failover switching in dual Ethernet models.
Added the enable port setting EPORT to all the communications ports
to enhance port security.
Added the MAXACC setting to the front panel to control limited or
full access to the front panel HMI.
Added fault location data to the IEC 61850 ICD file.
Doubled the SELOGIC processing capacity in the relay.
Revised the firmware to add the VSCONN setting allowing the user to
choose between VS input (synchronism check element) and external
3V0 input (broken-delta) for use with zero-sequence voltage polarized
directional elements and fault location.
Revised the firmware to address an issue with Fast Message that did
not report the MIN/MAX analog quantity value correctly.
Resolved an issue that involved phase identification logic where, in some
cases, the phase LEDs did not latch correctly when a trip occurred.
Revised the firmware to remove option D from the NETPORT setting.
Modified the firmware to make the MATHERR Relay Word bit visible.
Resolved a synchrophasor voltage magnitude issue for applied voltages of
200 V or higher with the settings combination FNOM := 50,
MRATE := 25, PHCOMP := Y, and PMAPP := NARROW.
Revised the firmware to address an issue where the oldest 180-cycle
event or HIF event was disappearing from the event history after the
relay was power cycled or restarted with STA C.
Modified the prompt for DNP Master IP Address DNPIPn to
distinguish them from the device IP Address.
SEL-751-R111
SEL-751 R111 was not released. R112 follows R110.
Table A.2 R100 Series Firmware Revision History (Sheet 2 of 5)
Firmware Identification (FID) Number Summary of Revisions