6/02
2-289
DC1632/2240
16-776 Image Conversion, 16-777
Status Indicator RAPs
Prelaunch Training/Review
16-776 Image Conversion
An error has occurred due to other causes than HD Access during image conversion process
by S-Formatter.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform the operation again.
16-777 HD Access
The HD Access Error has occurred during image conversion process by S-Formatter.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Replace the HD (PL 13.1) and perform the operation again.