6/02
2-393
DC1632/2240
116-380, 116-381
Status Indicator RAPs
Prelaunch Training/Review
116-380 MF UI Cont Soft
Fatal error of MF UI cont
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the ESS software.
If the problem continues, replace the ESS PWB (PL 13.1).
116-381 Data Link Layer Error between Cont and UI
Panel
Controller - MF UI panel: Communication error on the Data Link layer
At the communication between the ESS and Panel, the ESS detected an initialization error of
SCOPE, a message sending error, or retrieve error of the received data.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the ESS or Panel software.
If the problem continues, replace the ESS PWB (PL 13.1).
If the problem continues, replace the Control Panel (PL 18.2).