6/02
2-393
DC1632/2240
116-380, 116-381
Status Indicator RAPs
Prelaunch Training/Review
116-380 MF UI Cont Soft
Fatal error of MF UI cont
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the ESS software.
If the problem continues, replace the ESS PWB (PL 13.1).
116-381 Data Link Layer Error between Cont and UI
Panel
Controller - MF UI panel: Communication error on the Data Link layer
At the communication between the ESS and Panel, the ESS detected an initialization error of
SCOPE, a message sending error, or retrieve error of the received data.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the ESS or Panel software.
If the problem continues, replace the ESS PWB (PL 13.1).
If the problem continues, replace the Control Panel (PL 18.2).

Table of Contents

Other manuals for Xerox DocuColor 1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox DocuColor 1632 and is the answer not in the manual?

Xerox DocuColor 1632 Specifications

General IconGeneral
BrandXerox
ModelDocuColor 1632
CategoryPrinter
LanguageEnglish

Related product manuals