6/02
6-21
DC1632/2240
General Procedures and Information
Prelaunch Training/Review
720-xxx ESS Meter/Counter NVM List
740--xxx IOT Manager NVM List
719-010 ADF Major Version 0 0~65535 ADF Major Version No.
719-011 ADF Minor Version 0 0~65535 ADF Minor Version No.
719-012 ADF Revision Version 0 0~65535 ADF Revision Version No.
719-013 ADF Patch Version 0 0~65535 ADF Patch Version No.
Table 4 Chain 719
Chain-Link Name Default Range Description
Table 5 Chain 720
Chain-Link Name Default Range Description
720-002 Billing PFV BILL-
ING TYPE1
1~6 1 = Billing1, 2 = Billing2, 3 = Billing3, 4 = Billing4, 5 = Billing5, 6 = Billing6
720-003 Master Print-Full Color - 0~1999999 0~1,999,999
720-004 Master Print-Color1 - 0~1999999 0~1,999,999
720-005 Master Print-Color2 - 0~1999999 0~1,999,999
720-006 Master Print-B&W - 0~1999999 0~1,999,999
720-012 Backup1 Print-Full Color - 0~1999999 0~1,999,999
720-013 Backup1 Print-Color1 - 0~1999999 0~1,999,999
720-014 Backup1 Print-Color2 - 0~1999999 0~1,999,999
720-015 Backup1 Print-B&W - 0~1999999 0~1,999,999
720-040 [PSW Display] Group 0 0~999999999
999
0~999999999999 (0 means not set up)
720-041 TBD 0 0~999999999
999
0~999999999999 (0 means not set up)
720-042 TBD 0 0~3 0 = FreeAccess, 1 = Color Only, 2 = B&W Only, 3 = Cannot be used
720-043 TBD 0 0~3 0 = FreeAccess, 1 = Color Only, 2 = B&W Only, 3 = Cannot be used
720-044 Group C Mode to use 0 0~3 0 = FreeAccess, 1 = Color Only, 2 = B&W Only, 3 = Cannot be used
Table 6 Chain 740
Chain-Link Name Default Range Description
740-024 RegiCon Request Flag 0 0~255 0 = Performed, 1 = Not performed
740-025 Edge Check Request Flag 0 0~255 0 = Performed, 1 = Not performed
740-026 ProCon Request Flag 0 0~255 0 = Performed, 1 = Not performed