SYSTEM MONITORING AND TROUBLESHOOTING
CORE GENERATION
When any service running on the system crashes, the core file will be saved in
user:/cores.
ENVIRONMENTAL INFORMATION
The show environment command displays the latest known sensor readings
from the occupied slots that contain the line cards. The standard readings are the
temperature from the card and voltage readings taken at various places on the
card. The sensor readings are monitored to ensure that they are within the
defined ranges and if not, the card may be powered down.
The command can show individual card readings, or display the readings for all
occupied slots. For each slot displayed, the report includes the slot number and
card type, last time the card’s sensors were reported, and the values of the
temperature and various reference voltages on that card.
The sensor readings are monitored to ensure that they are within safe operating
ranges, and if not, the card may be powered down (see section “Managing
Individual Slots”). Any deviation will be noted in the log.
EXAMPLE
ALU(config)# show environment
Chassis environment readings
Report generated at Fri Apr 23 15:28:44 2010
Chassis temperature: 37C
T1/E1 - Four port T1/E1
Slot number 1
Liveness failures will report once
PCI configuration status: Ready
Reported at Fri Apr 23 15:28:40 2010 (4 seconds ago)
Temperature reading: 39.000C
Voltage reading: 5.10V(2%) 1.28V(0%) 2.47V(0%)
SE - Services engine
Slot number 3
Liveness failures will report once
PCI configuration status: Ready
Reported at Fri Apr 23 15:28:43 2010 (1 seconds ago)
Temperature reading: 30.000C
Opteron temperature : 33.0C
Opteron status : Active
Voltage reading: 5.04V(0%) 1.31V(1%) 2.49V(0%)
Command (in SUM/CM) Description
show environment [slot <0-3>] This command shows the environmental
state of the various parts and modules in
the system.

Table of Contents

Other manuals for Alcatel-Lucent OmniAccess 5740

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniAccess 5740 and is the answer not in the manual?

Alcatel-Lucent OmniAccess 5740 Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniAccess 5740
CategoryGateway
LanguageEnglish

Related product manuals