TROUBLESHOOTING T1 LINES
This section lists the commands to troubleshoot the T1 line cards.
T
O ENABLE LOOPBACK
EXAMPLE
The following example establishes a loopback of the incoming T1 signal on
controller T1 0:
ALU(config)# controller T1 0/0
ALU(config-controller T1)# loopback network payload
The following example disables the loopback on the controller T1 0:
ALU(config)# controller T1 0/0
ALU(config-controller T1)# no loopback
Command (in CCM) Description
loopback {local|network
{line|payload}}
Use the loopback controller
configuration command to put the T1
or E1 line into loopback mode. It can
be used to verify connectivity.
no loopback The “no” command disables the
loopback mode set on the interface.
The default loopback for T1 lines
is Local.

Table of Contents

Other manuals for Alcatel-Lucent OmniAccess 5740

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniAccess 5740 and is the answer not in the manual?

Alcatel-Lucent OmniAccess 5740 Specifications

General IconGeneral
BrandAlcatel-Lucent
ModelOmniAccess 5740
CategoryGateway
LanguageEnglish

Related product manuals