System Monitoring and Troubleshooting
Except on the first page, right running head:  
Heading1 or Heading1NewPage text (automatic)
110
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
Acceptable voltage range is +/- 6%. Acceptable temperatures vary depending on 
the card type, but generally range from 0 - 60
0
C. Warnings will be logged and the 
fan speed adjusted if any of the cards show a temperature greater than 50
0
C.
SYSTEM HARDWARE INFORMATION
The show chassis command provides a physical inventory of the chassis’ 
components, including parts that are in meta-slots (i.e., not line cards). Generally, 
it depicts the static information about the hardware configuration. The command 
can be used for a specific slot or to view information for the entire chassis. 
The command reports on the pluggable as well as non-pluggable (front panel) 
components of the system. These reports are available in common format. This 
command is available at all configuration modes.
EXAMPLE
ALU(config)# show chassis
        Physical inventory at Thu Jul  8 14:49:33 2010
        System started approximately Thu Jul  8 14:29:53 2010
        Uptime is 0 days 0 hours 22 minutes 10 seconds
T1/E1 - Four port T1/E1 (active)
        Slot number: 1
        Part number: 902604-90
        Manufacturer:  ALU
        Description: Four port T1/E1
        Serial number:  DG0820000252
        Version: 03
        Revision: 00
        LoL firmware version: 2.2.71
        Loader version: 2.35
        ALU-OS version: 3.0.0
SE - Services engine (active)
        Slot number: 3
        Part number: 902601-90
        Manufacturer:  ALU
        Description: Services engine
        Serial number:  DG0818000126
        Version: 02
        Revision: 00
        CPU Version: 1 (Low Power Opteron)
        Opteron CPU Version: 1 
Command (in SUM/CM) Description
show chassis [slot <0-3>] This command provides a physical 
inventory of the chassis components for 
a specific slot or for the entire system. It 
does not indicate the liveness of the 
elements listed.