Ethernet OAM (Operations, Administration, and Maintenance)
Left running head: 
Chapter name (automatic)
422
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
Alcatel-Lucent
f) Administratively bring up a MEP.
OA5740-A(config-oam-domain-assoc-mep)# no shutdown
g) Enable a continuity check protocol on a MEP.
OA5740-A(config-oam-domain-assoc-mep)# ccm enable
O
N OA5740-B
a) Enter the OAM Configuration Mode.
OA5740-B(config)# oam
OA5740-B(config-oam)#
b) Configure maintenance domain (MD) and a its identifier. 
OA5740-B(config-oam)# eth-cfm domain 1 name string domain123 
level 6
c) Configure maintenance association and its identifier (MAID) within 
maintenance domain.
OA5740-B(config-oam)# eth-cfm association 1 domain 1 
assocName string asso123
OA5740-B(config-oam-domain-assoc)#
d) Configure remote maintenance association end point and its identifier within a 
MA.
OA5740-B(config-oam-domain-assoc)# remote-mep 1
e) Configure maintenance association end point identifier.
OA5740-B(config-oam-domain-assoc)# mep 10 direction Down 
interface GigabitEthernet 3/0
OA5740-B(config-oam-domain-assoc-mep)#
f) Administratively bring up a MEP.
OA5740-B(config-oam-domain-assoc-mep)# no shutdown
g) Enable a continuity check protocol on a MEP.
OA5740-B(config-oam-domain-assoc-mep)# ccm enable
V
ERIFICATION
Verify OAM association information using the show commands.