RESET THE USER CONFIGURED SUPERADMIN PASSWORD
In case of accidental loss of user configured superadmin password, you will be
able to reset (but not recover,) the password as long as you have the physical
access to the device over the console. For this purpose, there is a special user
defined in the system called "recovery". This user login is valid only over the
console. The default (non editable) password for this login would be the chassis
ID, which is displayed as part of chassis information in the CLI. The serial
number of chassis is considered to be the chassis ID. It could be obtained
through "show chassis" command in this way:
E
XAMPLE
ALU(config)# show chassis
Physical inventory at Thu Jul 8 14:49:33 2010
System started approximately Thu Jul 8 14:29:53 2010
Uptime is 0 days 0 hours 22 minutes 10 seconds
T1/E1 - Four port T1/E1 (active)
Slot number: 1
Part number: 902604-90
Manufacturer: ALU
Description: Four port T1/E1
Serial number: DG0820000252
Version: 03
Revision: 00
LoL firmware version: 2.2.71
Loader version: 2.35
ALU-OS version: 3.0.0
SE - Services engine (active)
Slot number: 3
Part number: 902601-90
Manufacturer: ALU
Description: Services engine
Serial number: DG0818000126
Version: 02
Revision: 00
CPU Version: 1 (Low Power Opteron)
Opteron CPU Version: 1
Opteron CPU Frequency: 2193 MHz
LoL firmware version: 2.2.71
Loader version: 2.35
ALU-OS version: 3.0.0
MDC
Serial number: DG0818000008
Revision: 00
Version: 03
BP - ALU OA740 chassis (passive)
Slot number: 29
Part number: 902610-90
Manufacturer: ALU
Description:
Serial number: DG0812000678
Version: 00
Revision: 00
Base MAC: 00:11:8b:02:91:00