SAW sensor – Parameter
Type 8098 FLOWave L
15.4.8 Resetting the default values of the error limits, the warning
limits and the hysteresis of the volume ow rate

on the DN of the measurement tube:

low error value: opposite value of the high error value,

low warning value: opposite value of the high warning value,


do the following:
Go to the CONFIGURATION view.
SAWsensor
Parameter view.
Stand.meas.values
Volumeow
Limits
Resettodefault

The limit values and the hysteresis value are reset.
